Zhejiang, China
Business Type:
Manufacturer/Factory, Trading Company
Registered Capital:
100000 USD
Plant Area:
>2000 square meters
Management System Certification:
ISO 9001
Average Lead Time:
Peak season lead time: 1-3 months
Off season lead time: one month
OEM/ODM Service

Rubber Ball on-Line Cleaning system, Condensor Cleaning System, Central Air Condictionor Cleaning System manufacturer / supplier in China, offering Condensor Cleaning System on-Line for Sponge, Rotary Decanter for Sewage Water, Flm Permanent Filter Vacuum and so on.

Gold Member Since 2007
Audited Supplier

Condensor Cleaning System on-Line for Sponge

Get Latest Price
Min. Order: 1 Piece
Port: Shanghai, China
Transport Package: Polywood Case
Payment Terms: T/T
Output Type: AC Three Phase
Gas Source: Gas
Certification: CE, ISO
Power: <50kW
Standard: Standard
Specification: 5M3

You Might Also Like

Loading...

Basic Info

Model NO.: FL
Trademark: FLOURISH
Origin: China
HS Code: 8421299090

Product Description


Condensor Cleaning System on-Line for Sponge
Rubber ball cleaning system for central air conditioner condenser and evaporator pipe or heat exchanger.

Rubber ball cleaning system for power plant
Rubber ball cleaning system  - a brief introduction
For  the economic benefit, the rubber ball cleaning system  must be installed. The central air conditioner condenser and evaporator pipe are very easy to scale, and normal water treatment should be done in the summer cooling period. Otherwise, the inorganic salt dissolved in the water will crystallize with the increase of temperature in the environment of high hardness water. Scale is formed on the wall of condenser surface, resulting in reduced heat exchange efficiency. At the same time, when the hard scale increases, the energy consumption increases and the hard scale will increase 6%~10% when the hard scale 1mm is thick; the dirt, sediment and humus of the water, as well as the bacteria and algae, and the biological mucus formed by the microorganisms and their secretions, will attach to the wall of the condenser heat transfer tube to form the dirt. Slime can affect heat exchange efficiency, consume more power, cause high pressure operation, and cause overpressure shutdown when serious. All these seriously affect the normal operation of heat exchanger.
The condenser rubber ball cleaning  system  is the best equipment to effectively clean the cooling pipe of the central air conditioning main engine. The performance of the device directly affects the cleaning degree and heat transfer effect of the cooling pipe of the main engine. In recent years, the market of central air conditioning has been widened, and the condenser on-line cleaning device is widely used in the cleaning of the central air conditioner, and the effect can be achieved without reducing the load in continuous work.

Condenser is a very important part of power plant equipment. From the thermodynamic point of view, condenser plays a role of cold source in the thermodynamic cycle of steam power plant. When the initial parameters of the turbine are constant, the condenser's temperature is reduced by 10 degrees, the efficiency of the device is increased by 3.5%, and the steam turbine power is changed by 1%--2% for each change of 1kPa. Because of the fouling in the condenser pipe in the thermal power plant, the clogging of the dirt in the condensing pipe leads to the decrease of the heat transfer efficiency of the condenser and the increase of the steam turbine exhaust pressure, which eventually leads to the loss of the output energy of the generator set. Therefore, keep the condenser heat exchange pipeline clean and improve the heat exchange efficiency of the condenser. It has a very important influence on improving the thermal efficiency of the whole unit. The condenser rubber ball cleaning device is an important equipment to improve the cleanliness of the condenser and improve the thermal efficiency of the steam turbine generator unit. With the help of the flow, the clean rubber ball, which is slightly larger than the inner diameter of the condenser's cooling pipe, is squeezed through the cooling tube, and the inner wall of the cooling pipe is repeatedly scrubbed, and the impurities are taken out, thus improving the cleanliness of the cooling pipe, avoiding the corrosion and prolonging the service life of the cooling pipe. The device can be used under the condition of no shutdown and no load reduction. The vacuum degree of the condenser is improved and the thermal efficiency of the steam turbine is improved.
The technical specifications and corresponding requirements of condenser rubber ball cleaning system are as follows:
Technical indicators: the rate of receiving the ball is more than 96%
To ensure that the system achieves a higher ball collection rate, the following work is necessary:
1, the four corners of the condenser water chamber should be lined with steel plates to eliminate the right angle eddy region. Before the system is put into operation, it requires no blockage and no scaling.
2. Sponge hole size of sponge rubber ball should be uniform and connected with each other, without smooth skin. Soaking in 80 C water should not be aged, loose and wear resistant.
3, if there is no two screen installation, the accuracy of filtering is not greater than 10 * 10 (mm).
4, the installation position of the rubber ball pump should be close to the receiving net as far as possible, and the entrance height of the rubber ball pump is lower than that of the receiving net outlet.
5. The laying of pipes for rubber ball automatic cleaning system should minimize the number of elbow and the change of plumb direction to reduce water resistance.
6. The speed of water flow in the condenser's cooling pipe should be between 2.5m/s and 1.7m/s.
7. In the condenser water chamber, except for the inlet and outlet of the circulating water pipe, other outlets to the outside are equipped with an aperture of 7 x 7.
(mm) a net cover. The diaphragm of the water chamber is tightly combined with the end cover without a series of cracks, and there is no narrow gap in the water chamber.
Working principle of condenser rubber ball cleaning device
Selecting suitable sponge rubber ball, the wet path of the ball is slightly larger than the inner diameter of the cooling tube (about 1 to 2mm) and the wet proportion is similar to that of the water. The rubber ball is put into the loading chamber from the hand hole of the loading chamber, and the number is about 10% of the copper tube of the condenser inlet chamber. Then start the rubber ball pump, open the ball valve at both ends of the system, the glue ball is driven by the slightly higher water inlet pressure of the circulating water, and enter the condensate water chamber. Because the rubber ball is a multi soft elastic body, it is squeezed through the cooling pipe under the influence of the pressure difference of the circulating water inlet and outlet. The inner diameter of the cooling pipe is wiped, so that the dirt on the inner wall of the tube is brought out with the water. The rubber ball circulation water passes through the water pipe into the receiving net, and the rubber ball is separated from the ball net, and the rubber ball is separated. The pump is pumped back to the rubber ball chamber, so that the condenser tube can be cleaned continuously.
Composition of rubber ball cleaning device
(1) the two filter net: the two filter is one of the main equipment of the cooling water purification device. It clears all the sundries above 6mm, and plays a key role in ensuring the smooth and unobstructed of the rubber ball and the normal work of the condenser. (see Figure two) detailed working parameters and so on refer to "two filter net" special instructions. The electric rotating high pressure water recoil two filter net structure form 2, it mainly consists of: (1) shell (2) stainless steel net core (3) high pressure nozzle (4) transmission mechanism (5) reducer (6) and other six components.
(2) collecting ball net: the ball net is the key equipment in the rubber ball cleaning system. It is installed on the outlet pipe of the condenser and its function is to separate the rubber ball from the cooling water.
 

Send your message to this supplier

*From:
*To:
avatar Ms. Lucy
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now